Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we use shunt coil in breaker??????????

Answer Posted / ajmal

1. it will trip the mccb, in case of overload

Is This Answer Correct ?    7 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to failure indution motor insulation & how to improve heat in motor insulation

1889


transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?

2099


Why colled 440V to 3-phase supply.

2154


What are the characteristics of negative feedback?

1072


How to design harmonic filter at the project stage without nowing the harmonics levels

2218


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2191


what are the applications of transistors with low dc gain, high dc gain and medium dc gain( beta)?

1778


Tell me about ur past electrical maintanence job

1882


Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel

2028


why tertiary winding is used in transformer with diagram?

2255


if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer

1897


what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.

2340


how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?

2115


what is the use of sdf?

2103


any earth foult trip the relay but in welding time not trip by earth foult

3181