Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

defination of generator

Answer Posted / obulesu.e

Which Produces or generates the power is called generator

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can anybody just suggest about the scope of Electrical design with ETAP software?Just guide me?

3785


why dc is used in control circuit for mv & hv switchgear instead of ac

1904


What is called limb of a transformer?

1018


how to calculte capacitor range for single phase induction motors??pls tel

2110


Dear friends I want to design busbar for1600 kva transformer(i.e2100 amps) what are all the factors to be considered before selectinga busbar what are all the standard sizes of busbars what is the formula for finding current of copper and aluminium busbar

1873


if 2 coil of 1000W connect in series and 200 v is applied across it . then what is the total power of coil when coil have only resistive load .

1939


WHY RATING OF VCB NOT LESS THAN 630A

2602


what is x'mer ,isolation x'mer & yltra-isolation x'mer?????

2454


How do we calculate the Out put voltage of generator, after the excitation is being given?

1911


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1908


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1951


how many current required for hypo test

1955


What current flows in the transformer primary when its secondary is open?

1220


which pump used in STP

2192


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

2583