do we people experience any shock if we catch any one of
the three phases (R Y B)in air with out touching ground.
Answer Posted / pillay
NO.
To experience any shock current must flow in and out.
| Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
Why back emf used for a dc motor? Highlight its significance.
What is the drawback of class b amplifier?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
what are the applications of transistors with low dc gain, high dc gain and medium dc gain( beta)?
What is the formula to calculate the rating of power cable for three phase current.
what is the role and fuction of automatic transfer switch in rotary ups
Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.
My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible
a starter used for squirrel cage induction motor?
Why is remote backup preferred to local backup?
what is the difference between droop mode and ischnorous mode in thermal powerplant?
What are linear and non-linear systems?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is the difference between RMS & TRUE RMS VOLTAGE