Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

working of a diesel generator.

Answer Posted / suvrajit mishra

Actually,when the mechanical energy is provided to
alternator placed in a magnetic field rotating magnetic
fields(RMF) are generated to the rotors of generator,which
are cancelled by existing magnetic field,resulting into emf
into the stator finally flowing of current into the stator.

Is This Answer Correct ?    16 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much of the total hydro power potential has been exploited so far in india?

1123


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1990


Why we use mho Relay in long transmission line?

1455


Why the power generated in dams is complex power? Why the generators in dams cannot produce Real power directly (i.e power which has zero reactive part)?

1782


Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة

1398


How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?

1917


While HT line put on to activate ACB in low tention panel VCB tripping instantly.why it happens

2088


i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.

1626


Draw the DOL starter and star delta starter drawing?

2996


In MEP Services what are parts of STP and what are there function?

3555


what could be the RMS value and average value of a 4 phase sine wave?

1884


What is “pu” in ee?

1091


What are approaches to tackle sedimentation problem of reservoir?

1022


If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.

1971


I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.

2623