Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we used capacitor in induction motor?

Answer Posted / gunasekaran

To improve the power factor of the motor. motor is inductive
load it draw reactive power from system.so we have
compensate the reactive power component from capacitor.for
single phase motor capacitor used for stating purpose
also.and single phase motor are low power factor motor
because due to large air gap B/W stator and rotor so it draw
more current from system.so capacitor are use in induction
motor

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.

1977


how to measure dc earth leakage current?

3179


What is the distance between body earthing and neutral earthing.?

5031


what is the difference between active power and reactive power and apparant power in practical as well as theoritical

1941


do you have some of interview Questions in power and genrator section in general whith answers

2186


Is it possible to connect a safety device in to parallel?

2157


We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's

1924


Readings of ER300P Trivector meter

6425


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1755


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1964


what is the necessary of using inductance property in transmission lines even through resistance is used to opposes the high current flows in that?????

1898


How isolater function when installed inelectrical 440V wiring

2241


what happen when power factor of 2 parallely operated transformer become equle?

2210


Inverter. converter. Ups.MCB.solar.alternators. motors.

2000


i want to know d working mechanism of tafe tractors next i like to know d engine type of apache bighs can anyone help me

2245