In three pin socket normally three pin in between three
pins earthing point is more thickness why?
Answer Posted / rakesh
as we know that R=p*l/a
resistance of the
conductor is inversely proportional to the cross sectional
area of the conductor .Hence bigger cross sectonal area
reduces the resistance and provides a easy path for the
current flow.So the Earth Pin is always bigger than the
other two pins in a 3pin plug.
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
What is the purpose of stand by earth fault protection for transformer ?
what is the correct format to create a resume for interview??
Difference between megger test equipment and contact resistance meter test instruments?
Actuality I have at home electrical panel with 220v 50hz, and I want to converter from there to 110v 60hz, to wiring on the half of my house. Also I like to keep another half of my house with the original 220v 50hz. What is the best and safety way to do?
describe the Operation of induction generators from bus bars
why do we not use equivalent voltage source in negative sequence equivalent ckt.
what happen when increase or decrease size of lamp,light.glass.
What are the differences between single phase and three phase?
5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch
What is the principle of HIGH SPEED DIRECT DRIVE MOTOR ?
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
How do we find the rating of a transformer, if it got burnt badly.
Battery is a voltage source? give one example of current source and why?
Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used