Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Residual voltage & residual current used in which
protection?

Answer Posted / darshan thakur

Resudal current is used for unbalance protection.& also for
earh fault protection we are used open delata connection of
potential transformer.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

pls tell me about ups internal connection & we have given only 3 phase supply to ups system how get 4 wire (R Y B N )

2800


how to calculate the lightning arrester conductor @ no of earth pits required

2168


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2322


What is force on parallel conductors ?

1137


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1888


Why colled 440V to 3-phase supply.

2213


why dc is used in control circuit for mv & hv switchgear instead of ac

1968


If one lamp connects between two phases it will glow or not?

1126


What is vacuum circuit breaker.define with cause and where be use it device?

1368


what is the terminal voltage of dc series generator running at rated speed at no load?

7728


If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1931


what is physical distance of isolator to VCB in 33/11kv sub stations

2173


Where should the lighting arrestor be placed in distribution lines?

1184


If I want to buy a new Xformer for my plant what are the main parameter will I need to check?

1938


HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?

2676