If the load of transformer is getting more than its
rating,,,than how to overcome this problem? Suppose thee
rating of transformer is 315kva and the load is going
beyond than the rating say around load: 352kva...
Than how can we solve this problem without deducting the
load.
Answer Posted / v sridhar
in my view, whenever the load of a transformer is increased
there is a corresponding increase in its current as in our
case load is surpassing the rated value of the transformer
the current too will surpass the rated value causing the
load losses to increase beyond permiisible value causing
excessive heating of the coils, etc if this heat is not
dissipated quickly only then the problem of burning of
coils will arise, if by means of forced cooling etc we are
able to disssipate heat faster then the problem can be
solved to certain extent atleast the coils won't get burn.
Although the efficiency will go down as pointed out by
previous posts. Because in rural parts of india overloading
of distriution transformers is a very common phenomena...
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
what are the applications of transistors with low dc gain, high dc gain and medium dc gain( beta)?
what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.
how to build a network which step down 415v to 1v rms
where solid grounding and where grounding through ngr done and why?
what is mean by parallel operation of permanent magnet generators
What are the functions of different probes used in cro?
What is difference is of VSD,VFD,VSDS, are they the same as the direct current to control dc using above mention
State the methods of improving power factor?
what is the working principle of energy saver control panel. please give the complete calculation & theory.
HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?
dear sir, i completed diploma in electrical in 2005, how i can get electrical supervisor liance in mumbai
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
How to decide and select the different earthing wire size for the different types of earthing
why swinburnes test cannot be performed on series machines?explain
how we calculate torque ? how we improve it ?where torque will either motor or generator ?