Answer Posted / vinesh prajapati ,guj. +919974
1) Reduces HYSTERESIS due to function at gland portion
2) Improves Linearity
3) Works as a volume booster and Thus improve the speed of
Actuator opretion
4) Works as a span amplifier when spring range of actuator
is not 0.2 to 1.0 Kg/Cm2
5) Required whenever spli range control is required
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
What is mean by analytical instrumentation?
I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
what is the difference between magnetic flow meter and mass flowmeter
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
Explain plc level and its type?
How many types of sensor
what is a half wave, full wave, and bridge rectifer.
What is the main difference between Cavitation and Flashing?
If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?