what does the regenerative braking mean?and how it used for
Dc motor? thanks.

Answer Posted / t.somasundaram

regenerative braking is a method which is used to to stop
the DC motor immediately against moment of inertia.A
regenerative brake is a mechanism that reduces vehicle speed
by converting some of its kinetic energy into a storeable
form of energy instead of dissipating it as heat as with a
conventional brake. The captured energy is stored for future
use or fed back into a power system for use by other
electrical equipment.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What's mean HVF & HAF in Vacuum Circuit Breaker?

4726


L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.

663


what is mean by Digital Logic Meter (DLM)

1858


how we can calculate chiller required ampear?

1590


For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?

1529






how to calculate short circuit current for the busbar

949


hi all i like to know vat is power plot in control systems also i want to know abt latest trends in electrical & electronics

1451


Would you recommend to replace all oil filled cables with xlpe cable for hv transmission with the current technolgy for xlpe cable?

1059


working of diesel generator ?

1353


how can we select the appropriate VCB ?

1818


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

4476


diff. between tension mode & speed mode

1768


Is there any specialised book to refer about fault level calculation both in MV and LV side??

1558


What are gain margin and phase margin?

832


how to calculate the size of the HT cable

1415