Answer Posted / anusha
WHEN TWO CONDUCTORS ARE CONSIDERED WITH LARGE DISTANCE
BETWEEN THEM, THAN ITS DIAMETERS.ON APPLYING A.C VOLTAGE
BETWEEN THE CONDUCTORS THE ELECTROSTATIC STRESS IS PRODUCED
IN SURROUNDINGS OF CONDUCTOR IN ATMOSPHERE WHICH CAUSES TO
FAINT VOILET LUMINOUS GLOW WITH HISSING NOISE ALOBG WITH
OZONE GAS,IN LONG TRANSMISSION LINE, IS CALLED CORONA
EFFECT.
| Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
1.What will be stored in online ups EPROM IC?
Can we indroduce the principle of single phase induction mator to Transformer? i.e. by Producing rotating flux in the transformer.
What is the reason that the humming sound is coming from the induction furnace panel?
What is the main use of rotary phase converter ?
The moisture in air will condense at
what is submersible pump?what is different between motor and sub motor?
Define sensitivity?
There are Two questions about Steam Turbine Generator... What is HRSG bypass of LP, HP used for in power generation? In particualar, in the event that fault of HP bypass, there would be STG TRIP in operation but none on the LP bypass fault...what's the reason ?
why we can stote dc? why we cant store ac?
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.
What are the advantages of the three-phase motor over single phase motor?
Explain The Application Of Storage Batteries?