What is diff between Ingral orifice and simple orifice?where
it use?
Answer Posted / maneesh
as mentioned above integral orifice need not be attached
with transmitter.it can connect with a transmitter through
impulse line and is used for low flow rate.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?
How is automatic reference junction compensation carried out in temperature recorders?
how do we commission inergen system?
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
How to calibration coriolis flow meter?
how to calibrate corollaries (Mass flow meter)?
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
whats the abbreviation of IOP? is it instrument of power or input open problem?
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
what is basic difference between motion balance and force balance in pneumatic instrument?
selection criteria of control valve? and selection criteria of actuator explain in brief?
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?