Answer Posted / thowsif_emerson
single-throw" (SPST) (the simplest type, "on or off")
or "single-pole, double-throw" (SPDT), connecting either of
two terminals to the common terminal. In electrical power
wiring (i.e. House and building wiring by electricians)
names generally involving the suffixed word "-way" are
used; however, these terms differ between British and
American English and the terms two way and three way are
used in both with different meanings.
It is a Switch r what????
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
are there rmu for 3 transformer?
what is the cause of voltage dipp or swell in the transmission lines?
How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm
what is the necessary of using inductance property in transmission lines even through resistance is used to opposes the high current flows in that?????
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
Advantage of LT panel vs HT panel
How to know th details about an electrical Drawing ? Please mention the easy method.
What is gain margin?
what is through fault?
Difference between control junction box (cjb) and power junction box(pjb)?
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.
What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
What descriptive information does the NEC require to be marked on all conductors?