what is balanced beam relay

Answer Posted / thowsif_emerson

It consists of an iron armature fastened to a balance beam.
Under normal operating Conditions, the current through
the relay coil is such that the beam is held in the
horizontal position by the spring. When a fault occurs,
the current through the relay coil becomes greater
than the pick up value and the beam is attracted
to close the trip circuit. This causes the opening of
the circuit breaker to isolate the faulty circuit..

Log on to:-
http://electricalandelectronics.org/2008/10/30/electromagnet
ic-attraction-relays/

Is This Answer Correct ?    11 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is mean 2XWY

1982


What is an ac motor?

681


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

1599


ROC converges if pole and zero lies inside a) origin b) z=1 c) pole d) zero ? Explanation please? if ROC does not converges then?

2455


why occ characteristics curve in not tracing back when we are bringing back the rhoestat?

1427






WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.

1966


i want to put single phase load on scott connected transformer,eventhough how to balance the transformer.

1410


Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.

1254


WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.

1621


What is kvar?

854


What is purpose of reactor?.What is different between line and bus reactor?

1469


Why CBCT rating is 50/1A

2318


I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.

2115


Can u Explain about the electronic trivector meter and the use of data converters in them?

1886


What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?

1806