Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why fuse not recomended to neutral

Answer Posted / gopal prasad

Fuse is an device used to protrct the wireing,in case of
over current,short circuit conditions.When this type of
fault occurs in a system or failure of insulation, maximum
fault current flows in wire.If fuse is connected to the
neutal:
(i) fuse will not blow when phase is shorting with
earth line and cause fire hazard.
(ii)if fuse is blown off then also phase supply
(live)will be available which wilb dangerace for the peson
thinking that no power is available to the equipment.

Is This Answer Correct ?    22 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

whats the existence of reactive power and when it arises?

2114


Can we use both Electrical & mechanical interlock between tow breakers? if yes how, please explain

1483


The 3 phase Delta connection RB=440V, BY=350V,.......* is Line to Line voltage RY= ? And Formula....?

1698


what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group

2068


I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN

2068


I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)

2120


what is the working principle of energy saver control panel. please give the complete calculation & theory.

2425


can someone explain that how the speed of the protection system affects the fault level calculation?

2063


When we connect the large capacitor bank in series ?

1075


can we conduct the swineburne's test on a dc series motor? why?

2117


Dear friends I want to design busbar for1600 kva transformer(i.e2100 amps) what are all the factors to be considered before selectinga busbar what are all the standard sizes of busbars what is the formula for finding current of copper and aluminium busbar

1872


what are the advantages and disadvantages of speed control of 3 phase induction motor by varying frequency explain with drawing

2648


What is the effect of interchanging core(made of steel) and winding(made of copper) material in case of transformer? Give proper explanation in regard to different losses in transformer.

1864


What does bode plots shows?

1132


Please elaborate th´evenin’s theorem?

1128