Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Difference Between Induction Motor & Servo Motor

Answer Posted / darshan

as in induction motor stator is formed by coils while in
servo motor stator is formed with permenent magnet. so in
indution motor very high inertia is there while in servo
inertia is low. Due to that servo is very easy to stop at
instatnt. so it is used in position control while in
application where at instant position stop is not required
induction motor is used

Is This Answer Correct ?    187 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.

2234


What is highest size of HT motor like 11 kv or 33 kv,and how to make it 750 rpm.i think the size will be very big.any idea ? pl. reply..

1914


what is the differation bewreen kwh & fundamental kwh in electronic trivector meters

2182


brief notes on ammeters

2018


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

2163


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1371


how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?

2412


A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.

1051


please give me all the Alarm .Trip ,Safety Relays & Conditions of Diesel-generators mail me on ashokbabunhce@gmail.com

1954


what is relay what is protection & contact multiplying relays where it is used function in brief

1164


Define the overload capacity of the motor?

2021


What types of high speed CMOS circuits have you designed?

2117


What is the difference between DOL starter and star delta starter

1115


What is the unit of magnetic flux density?

1162


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

1987