What is the required value while doing the megering

Answer Posted / thowsif_csm_emerson

For Insulation Resistance Testing with Megger for for
electrical equipments, please refer to the following
publications:

IEEE Std. 43-2000: "Recommended Practice for Testing
Insulation Resistance of Rotating Machinery"
IEEE C57.125-1991: "Guide for Failure Investigation,
Documentation and Analysis for Power Transformers and Shunt
Reactors"
NETA ATS-2003: "Acceptance Testing Specifications for
Electrical Power Distribution Equipment and System".

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.

4960


which stabilizer is better ? AVR, Servo Stabilizer, Static stabilizer etc & why explain it

2420


what material is used in capaciter

1477


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

2763


Batteries. What is the difference between Lead and Nickel batteries ?

1695






Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?

1406


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

2980


L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.

677


Discuss about gear cutting machines.

796


What are the function of different components of servo motor?

1557


what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?

1678


how to discharge 3 phase power factor correction capacitors

1970


what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?

1825


What is phenomenon of electromagnetic induction and how it works?

623


list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.

1562