HOW many type of Circut Breaker in the world used in 400 kv
substation?
Answer Posted / kumar ravikesh singh
Above 66KV SF6 circuit breaker is used and below 66KV ACB
is used.
| Is This Answer Correct ? | 11 Yes | 6 No |
Post New Answer View All Answers
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.
What does ampere turns shows?
How to apply 'c' license and also explain what is difference between 'c' and 'b'license.i am also working in one of the private company.i have finished my diploma in 2014 .i have already finished in ITI electrician course.....
What is the source of dependent source ?
What are the basic elements used for modeling mechanical rotational system?
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
What are the advantages of vscf wind electrical system?
what do you mean by every IC 74 first digit.why are you using this no.why not using another no.
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
(1)Can earth and be conected together (2) what is the diferent between earth & neutral
why normally Generator rating are between 11Kv to 22Kv?
How is operate breaker failure scheme in substation
Why efficiency of generator is higher than motor at a particular load?