Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Stator of three phase induction motor creates Rotating
Magnetic field.But why not Transformer?

Answer Posted / rahul shewale

in stator of a 3 phase im windige are placed 120 degree
phase displacements from each othre.each phase produces its
own flux. these fluxes ara not having low reluctance
path.the resultant oo these three fluxes is a rotating
vector.so the flux is called rotating magnrtic flux
in transformer there is low reluctance
path so flux is not rotating

Is This Answer Correct ?    0 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what type of earthing do for dry fissure rock?

2429


how can maintaince the acb contactor moveing and fixing kit

2066


apti mainly on logical reasoning, verbal and non-verbal ability (70 percent) and remaining technical. I was in ee but technical had mech ques like on turbines and welding.

2170


hi frenz,its aswathy.i hve aplied for the hpcl test on feb,pls send the test patern & the placement papers as soon as possible. mail-id :kjaswathy@gmail.com

1778


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2323


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

2093


In both 600/1000 V cable and 450/750 V cable, we can supply 415 V. However for distribution, all utilities are using only 600/100 V instead of 450/750 V. What is the reason?

1962


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

2260


is all the servo motors having brake?please specify which servo motors having brake for stop on position and which are not.

1773


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

2961


can we do the star delta connection of capacitor for 3- phase motor starter.

2013


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1711


Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.

2358


We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?

1637


A 2083kva AVR was tested, phase to ground shows continuity, what is the implications

1020