Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do we use magnetic contactors ?circuit breakers are not
enough?

Answer Posted / ashwani malhotra

The main function of magnetic contactor is to prevent
accidently operation after the power failure & again
recovery. Because as soon as power fail the holding coil
release the contacts and it will not operate untill someone
complete the hold circuit again .

Is This Answer Correct ?    24 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

2520


why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

2369


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

2497


what is calculation mathod/formaulla for deciding Size of busbar (Copper/ aluminum)for L.T. panel on Various Fault level like 50kA,25kA,10kA

2848


What’s electric traction?

1198


Is better to supply the voltage for static exciter from the auxiliary power source or from the SG terminals? And why?

2001


i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?

2476


What is voltage divider rule?

1239


at what rate the micro controller increment its timer....is it 1micro seconds or 1/(12*10^6) seconds

1841


how can calculate 1kva generator running time in 1 liter keroscene

2661


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

2088


How to calculate energy stored in an inductance?

1186


Why line VTG = √3 phase VTG in star? How?

1675


difference between the applicability of nortons and thevenin theorem

2135


What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva

2272