Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is inrush curent.

Answer Posted / thowsif_emerson_csm team

Inrush current or input surge current:-

It refers to the maximum, instantaneous input current drawn
by an electrical device when first turned on. For example,
incandescent light bulbs have high inrush currents until
their filaments warm up and their resistance increases.
Alternating current electric motors and transformers may
draw several times their normal full-load current when
first energized, for a few cycles of the input waveform.
Power converters also feature high inrush currents relative
to their steady state currents. This is typically the
charging current of the input capacitance. The selection of
overcurrent protection devices such as fuses and circuit
breakers is made more complicated when high inrush currents
must be tolerated. The overcurrent protection must react
quickly to overload or short circuit but must not interrupt
the circuit when the (usually harmless) inrush current flows

Is This Answer Correct ?    21 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2266


Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.

5344


what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration

2179


can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com

2066


what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker

5331


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

2035


How would you relate your key competencies to this position?

2163


Why dry type cast resin transformers tap link blast in HV side while power shut down times on load?

2275


define superposition theorem thevnin theorem ,norton theorom?

2334


How is the percentage impedence of a transformer fixed at design stage???

1933


which type of cabel

2357


The electrical energy required to raise the tempreture of a given amount water is 200 kwh. If the heat losses are 20%, the energy required is?

1956


Why saturation region slowly shifted in the left side?

1810


How to calculate the sag on transmission Lines.

2922


why steady state stability limit is greater than transient stability limit ? How it can be explained ?