Why we use Carbon & graphite mixxed brushes in the DC motor?
Answer Posted / karthik raman.b
it has good peripheral speed and current density, self lubricating
| Is This Answer Correct ? | 4 Yes | 3 No |
Post New Answer View All Answers
how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........
Why mostly the HV side of transformer has Delta?
any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
What is resistance of 50meters, 16sq.mm, single core copper cable?
As an electrical engineer what are the responsibilities which i can hold in TCS?
what happen when we add mentos in cold drink?& why?
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
is it necessary to earth the rmu before cutting off the transformer winding?if yes why?
plz send me the syllabus or any sample paper for engineer trainee recruitment if any,on ravinder911@yahoo.com
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
In a tap changing transformer where is the tap connected, is it connected in the primary side or secondary side?
Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?