whats diffeence between dcs & scada operation.
Answer Posted / nagarajan singapore
DCS is nothing but distributed control system which is
controlling all parameter by distributing data to separate
unit from the master data base along with the field
bus .this is indeppedent control system.
SCADA is supervisory control and data acquistion system
which is monitor based control from plc i/o .this one
deppendent control control system by controlling a limited
control
Is This Answer Correct ? | 17 Yes | 0 No |
Post New Answer View All Answers
In turbine what does term CDP, NI, NH, HSSOC means.
What is the procedure of calibration of Load cell?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
State some of balance principle’ advantages?
What is the difference between mmwc and mmwg?
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
how to commission furnace ( water heater)
detail of mass flow meter pricipal
Define the terms Accuracy, precission, Spam, process tolerance while doing calibration of an instrument? Explaini with an example?
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
steps for installing orifice plate?
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem?
what is diffrance between FF & SMART, explain with difination