what is the difference between induction and synchronous
motor?explain in simple words?why 3 phase motor is given
preference over single phase motor.
Answer Posted / upendra
the diffrence is comes at their speeds.
IM runs at iess than synchronus speed
sm runs at synch speed
| Is This Answer Correct ? | 15 Yes | 5 No |
Post New Answer View All Answers
why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?
what is v/f control in VFD?
What does the term “voltage regulation” means?
"TRANSFORMER MODELING AND ANALYSIS" MEANS WHAT AND WHICH TOPICS U READ IN THIS
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?
features of hbc fuses
when will be the iocl interview results i faced interview on 8th september 2008 iam from electrical branch i faced interview for the post of electrical engineer??????????????????????//
what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)
Any Electrical Engineering jobs?Please refer for interviews. Thank you
63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?
why ht cable end termination don't have a gland?
What are the types of the glands and difference between single and double compression type of cable Glands.
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com