If the load of transformer is getting more than its
rating,,,than how to overcome this problem? Suppose thee
rating of transformer is 315kva and the load is going
beyond than the rating say around load: 352kva...
Than how can we solve this problem without deducting the
load.
Answer Posted / osadebe .c .patrick
In the first place an overload on a particularly rated
transformer is unacceptable by principle and experience,
Since we intend to achieve 352KVA load, i suggest we
increase the rating of the transformer to 423 KVA i.e 120%
of 352kva.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
BRIEFLY EXPLAIN THE STORAGE CLASSES AND THEIR TYPES IN C
High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?
to vary valtage from 0 - max a variac is necessary . so how to design for high power applications nearly about 200KW power
what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks
Is vtg is controlled by the resistor? if else how much?
What are the different types of transformers?
why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?
I am applying for NTPC examination.Can we please provide previous paper to my mail prasad.chintala108340@gmail.com
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
What is ST and specify its range of voltage.
please tell me how a surge protector work on a DC 48Volt.? please describe briefly.
How cable from Kit-Kat to main switch, from starter to motor are designed?
wish of these transformer uses oil?
what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws: