Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can anybody will tell me abiut PID controller.

Answer Posted / moody from egypt

PID CONTROLLER is aproportional integral differential
controller that may b used at any electrical control
application as the response of any system is resulting from
the multiplication of any gain "prop" , diffrentiate
it"diff" and then integrate it.
PSS is the most device at which we design it by PID
either with FLC or using POLE PLACEMENT.
u can make asmall pid using OPERATIONAL AMPLIFIER
OR SIMPLE RLC CIRCUIT.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hye SAM acn u send your e mail id, so that i can solve my query through e mail?

2232


Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.

1877


how to calibrate steam control valve in steam turbine

3312


how to calculate control valve bonnet size?? or how to select its material?

2408


Please tell me details about Sox,Nox,SWAS analyser????

3712


what is the input of digital counter during the the calibration time?

2298


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2188


what is the procedure of belt scale calibration?

2410


What is 3 element control system

1470


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2157


What is difference between Ionization heat and bimetallic heat

1623


What are the uses of orifice plates?

1071


I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.

2245


What is zone,loop/fire alarm system?

2632


What is zero elevation and zero suppression?

2141