Why Instrumentation Air Compressor called as
Instrumentation Air compressor?pls dont just tell its
trasferring IA to all transmitter,valves.I need exact
reason, please......................
Answer Posted / va
As instruments need clean air supply which should be mixed
with moisture and oil from compressor. For that purpose the
air dyer is used which heat,cool and filter compressed air,
which remove the all above. So it specially used for
instrumentation purpose. So it is called INSTRUMENTATION
AIR COMRESSOR
| Is This Answer Correct ? | 28 Yes | 0 No |
Post New Answer View All Answers
What is the use of double seated valve?
Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....
I have got a call of IOCL interview for projects having 2yrs experience. What sort of questions should I expect in the interview?
What is first echo & echo window in radar type level transmitter?
describe flow nozzel principle?
explain key exchanges in all security modes WPA,WPA2,TLS?
What is the use of gauge?
The Design Calculation of Level Transmitter For Different Structure open & Closed Vessel, Eg. Diff. Level Tx., Capacitance For Continous Operation
What is the difference between working pressure and calibration pressure of a control valve
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
Why mmwc unit is used?
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
What is hp & mp seperator .& what is its working principle ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =