What is the relationship between the universal
gravitational constant (G) and the acceleration due to
gravity (g)?
Answer Posted / gagandeep garg
F = G x M x m/ r2
E = F x r = (G x M x m/ r2) x r
E = mgr = (G x M x m/ r2) x r
=> g = G x M/ r2
OR G = g{r2/M}
where,
F = Force of attraction between twoo bodies(N/m2)
E = energy in smaller body w.r.t the heaviour body(J)
M = mass of heaviour body/planet (kg or slug)
m = mass of smaller body(kg or slug)
g = acceleration due to gravity (m/s2 or ft/s2)
G = universal gravitational constant (m3/kg/s2 or
ft3/slug/s2)
r = distance between the centres of the two bodies(m or ft)
The value of G is known and has been estimated by
scientists as:
G = 6.673 x 10-11 m3/kg/s2 in the Metric system
G = 3.439 x 10-8 ft3/slug/s2 in the English system
| Is This Answer Correct ? | 69 Yes | 39 No |
Post New Answer View All Answers
How to convert mmWc(mili meter water colam) to tph(ton per hour)?
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
Give Detail information about plc,dcs,and scada system?
How u measure the massflow in orifice flow measurement techniques
i want to find out iffco get test paper
How you calibrate absolute pressure with the calibration range of 0 to 1000 0C Absolute. Please explain the procedure for calibration.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??
what is thermo coupler and how it works
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
What is the PLC configuration in Cement industry?
hi i am eswar i want to know the instrumentation interview questations for eil(engineers india ltd) i have applied for engineer post in eil please help in this.my mail id eswar310@gmail.com
How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?
Describe the function of Accumulator into the Pump
what is the reason while warning lamp is on while the engine is cranking?