Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the isolation treasforfer are connected at out put of
the ups ig 200kva ??????????????????

Answer Posted / virender

To creat the neutral.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can a equal potential zone be carried out in conductors?

1311


What type of wiring series or parallel is used for conventional and addressable type FAS & why?

1785


what is under coal gassification?

2070


How colour picturetube works & how many year it will works.

2007


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2208


A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.

2100


What are locations arc protection relay is fixed.

1849


plz send me the syllabus or any sample paper for engineer trainee recruitment if any,on ravinder911@yahoo.com

2147


How many turns are there in primary winding? (In Transformer)

1683


why there using acb enclosure in big buildings

2078


what is the difference between Power and Distribution transformers ?

2135


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1775


how give earthing conection to household equipment?

2017


why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain

2246


why we permissive overreach in distance protection.where it is applicable to use in long r short lines

2742