what is difference between AC VVVF drive & Dc VVVF drive
explain their working principle?
Answer Posted / s.balamurugan
If frequency increase speed will increase, If frequency
decrease speed will decrease. so when the frequency is
zero, there is no speed(rotation).that means there is no Ac
voltage.so this voltage like dc (because there is no
frequency).
| Is This Answer Correct ? | 31 Yes | 6 No |
Post New Answer View All Answers
we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer
What is the difference between type1 and type2 relay protection co-ordination for motor feeders
Why PS class CT is always preferred for Differential protection?
Why collecting electrode of ESP to be earthed
where lt & ht capacitor used
What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
what is difference between earthingpits,earthing grid & earthing mess?
I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)
if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?
i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
How earthing of switchgear system to be done.
What are the basic components of the feedback control system?
How to calculate the multiplying factor for energy meter with ct ratio given