Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the advantage of DC Motor over AC motor & Where its
applicable ?

Answer Posted / phanendra babu

it is completely depends on the application i.e where we are
using the motor.if we require high starting torque dc series
motor is applicable or we require better speed vs current
chars. dc shunt motor is suitable,like wise depending upon
the application it will change. and the main advantage of dc
motor over ac is speed controlling ig very very easy
compared to ac motors.

Is This Answer Correct ?    6 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)

2252


What is the ratio of Booster transformer?

2166


When we connect the large capacitor bank in series ?

1091


why the frequency and voltage in india is 230v and 50HZ. when compared to USA say 110v and 60 HZ.

1442


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2150


how can i find cable size from current rating?

1765


how we can calculate power factor in single phase & three phase ?thank u

2004


how are reversing the direction of dc motor

1654


How does an oscillator differ from an amplifier?

1149


Did RMU have ct and pt ?

1360


briefly explain the main blocks found in a microprocessor based system

2192


how generator avr give to the input?

1999


how to calculate singlephase motor efficiency?

2239


What do you mean by lighting transformer?

1052


High speed earth switch operation with diagram

2488