Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the methods used to improve powerfactor ?

Answer Posted / sri valli

usage of synchronous motor also (where it is applicable
)also improves power factor

Is This Answer Correct ?    14 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is (+) and (-) in generator field detector stand for?

1826


how to decide the panel size like MDB ,SMDB PANEL SIZES

7332


when the Transmission and Distribution network where is the "feeder" lines are located? and why should be used in T&D network.....

1752


why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??

2277


i have interview in Pepsi company what type of question will ask please send the question and answeer

3433


I use 20 nos led tube 4feet, in pathway 100mtr approximate, so what size cable i use for lighting

1444


What is core CT & it's function?

2056


63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?

2724


What happened when voltage will half value of current ...

1588


Why you want to join non technical field when you are an engineer?

6732


what is the earth current,reverse power,electrical trip generator short circuit,low voltage, high voltage please discribe me

2097


What are the effects of adding a zero to a system?

1265


what is the difference between directional & non directional earth fault with example please explain.

1834


Diagram on interconnectivity of 11kv transformer with RMU (i.e, one incoming and two outgoing or two incoming and one outgoing)

2705


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2136