Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why should we place 9KV lightning arrestors in 11KV
substation ?

Answer Posted / a.umapathy

The reason is when ligtning impulse is more than 9kV the
lightning arrestor by pass the lightning impuluse so that
the 11kV system will be affected. If lightning arrestor
rating is more than the system working voltage (say 15kV)
then 11kV system will experience higher voltage which will
cause the damage in apparatus (as this designed for 11kV).
So insulation coordination of protective device must be
less than the device to be protected.

Is This Answer Correct ?    52 Yes 30 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

2029


what are the pecularity of shaver sockets ?

1967


why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving

2251


What is BusBar integrity test and how it is conducted?

2371


Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz

2355


What is slip in an induction motor?

1202


Why have to use copper cable for local isolator to motor ?

2146


A motor running with lenze frequiency inverter stops if I REDUCE SPEED with 25% load.If I run it in High speed and medium speed running smoothly with full load.please help me to solve it.

2041


We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.

1922


what is mean by D.O. in distribution line poles?

1743


What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.

1829


wat is the current produced in a 5000v megger? when the positive and negetive terminals are touched on our body get s shock?

1966


How Can you do Maintenance of ACB of 2000Amperes

2114


How do u analyse protection fault when vcb tripping on load

1701


Pl. give me checklist for installation & commissioning of machine tool.

2348