what is the relationship between horse power and watts
Answer Posted / varma
1hp-746watts
| Is This Answer Correct ? | 62 Yes | 6 No |
Post New Answer View All Answers
What is pi controller?
compare between starting charactristics of synchronous motor with those of 3Q Squirrel cage induction motor
How LT megger works ?
hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
What is the working principle of servo motor? And explain it.
How I can Compare 120v/60Hz versus 220v/50Hz ? Please tell me both advantage and disadvantage ......
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
I need bhel previous year quetion papers for electrical engineering department.I searched but i could not find out
Can we put 3 layers of cable tray while installing tray
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..
what is the working principle of a DG Set, Alternator, & exiter
why don't we use the generator as a motor? and what will happen?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??