Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the load amp for 1 HP 3 phase Motor ?

Answer Posted / navnit bhimani

1.5 AMP

Is This Answer Correct ?    115 Yes 19 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is KSR type transmission tower? What is LSR type transmission tower?

5334


please write motor, transformer, Generator setting, fault level calculation of Tr.etc

2012


What is Plank's Law?

1098


What are books to be referred for KPTCL exam?

3622


working of diesel generator ?

1790


A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.

1269


ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH

4117


send me all basic electrical question and answers

2864


what is differnce btwen lll and lllg faults

1949


Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.

5344


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1635


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

1938


why the perameters of secondary circuit are more important then that of the primary circuit of induction motor?

1847


How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?

4684


what is the use of permanent magnet generator in exciter

2099