Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

generally on the roadside v hav 11kv line which is being
step down to 440v line to line....so any1 can tell me which
type of transformer they r using whether it is star to
delta,delta to star etc...???

Answer Posted / bhanu

The transformer is Delta - Star connected Transformer i.e.,
11kv is given to Delta connected side and 440v is given to
Star connected side of the transformer.
Delta side dont have neutral, while transmission neutral is
not needed.if neutral is used totally 4 wires have to be
used otherwise 3 wires are enough. 440v side we give to
homes, there a neutral is need so connected in star.
in Delta side line voltage = phase voltage. so 11kv voltage
is same.
homes need the voltage of 230v, in star the line voltage is
not equal to phase voltage. line voltage is 440v and phase
voltage is 230v.
so the transformer needed is Delta-Star

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2

1849


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1821


xpression 'document.FrmQF.myemail' [

1951


hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.

1951


can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?

3228


What is the meaning of HT Trivector Meter ?

2387


What is creepage distance..... what will be the value for different voltage level

1928


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2061


there are cam operated switches - why we call cam operated , What is cam ?

1859


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

2034


What does the kvar means?

1140


What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer

1763


I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions

1556


Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?

2091


explain Density

1071