Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what s the differenc between electrical &electronis , how
to define them

Answer Posted / maroofkhan

actually electrical s/m works on frequency domain and
electronic s/m works on time domain.
electrical s/m works on high voltage & electronics s/m
works on low voltage(-15volt to +15volt)

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is method for testing CT

2095


can any tell me why slope 40% and 80% is calculated in differential protection?

1841


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1990


why we permissive overreach in distance protection.where it is applicable to use in long r short lines

2702


Why field rheostat is kept in minimum position?

1174


why lightning arrestor are made in two stack of insulator but why not cvt

2015


WHY SEPARATELY EXCITED MACHINE NEEDS EXCITATION BY DC SUPPLY WHY NOT BY AC

1836


we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.

1860


Why the earth to phase voltage is high 250 compare to other two phases

1463


What current flows in the transformer primary when its secondary is open?

1159


What is the difference between Delta & Wye windings?

2043


Can we use both Electrical & mechanical interlock between tow breakers? if yes how, please explain

1427


which type of motor is used in automatic swing gate

1954


what is the method of earthing of a transformer using electrodes?

2203


Determine the BTU size of an aircon for 20 sq metre room