Stator of three phase induction motor creates Rotating
Magnetic field.But why not Transformer?
Answer Posted / pugezhenthi.p
In transformer we provide the path [steel] for the
electromagnetic flux. So there is no interaction b/w the
flux. But in Induction Motor there is no separate path for
the magnetic flux. All the three phase fluxes are spread out
to the air gap, at the time only interaction b/w the flues
are possible. The interaction gives total resultant flux,
which is constant magnitude throughout the whole cycle, but
the axis of resultant flux is changes with respect to the
whole cycle. So we call this one as a Rotating Magnetic
Field[RMF].
| Is This Answer Correct ? | 2 Yes | 6 No |
Post New Answer View All Answers
A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.
how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me
difference between a diode and thyristor?
How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.
How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?
Discuss the effect of sudden loading of an induction motor
hi,every one, i have to write the search paper on "performance policy optimization" of NGN (next generation networks). i need the material on this topic. can any body help me. please tell me any useful site where the good material is available and name of any reference book. it should be a great help for me.
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?
What is the physical significant of power factor?
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?
how to carried out tan delta test in 11 KV alternator ?
how to find the capacitance value of the motor while running??
What is the power requirement of tamil nadu for one month?
How can we find out LT UG cable fault (size,from-4*25mm sqr to 4*300mm sqr)? How mani types UG cable faults?