Whats meant by trivector meter where it is connected at the
substation?

Answer Posted / pradyumna kumar jena

There are 3 types of electrical ernergies. These energy
parameters are vectors. They follow the Phythagourous
theorem. 1. VI, 2. VICos(phi), 3. VISin(phi). The sequence
is Apparent, Active and Reactive. Any meter, which
measuring all these three vectors is called Trivector. It
may be single or Three Phase, not an issue.

Is This Answer Correct ?    27 Yes 14 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can we determine size of a cable by knowing the kw or current rating of a load?how can we calculate the resistance box of a slip ring motor?

1301


what is difference between 9kv 5ka surge arrester and 9kv 10ka surge arrester.

1370


what happen if field of dc shunt motor opens? what is function of putting res. in parallel to one phase of 3 phase IM? the power supplied by 5A source in circuit is given by------Watt.

1532


How will calculate losses in an multi core Aluminium LT cable of different sizes & upto what length we can use a LT Cable ?

1648


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1351






What is mathematical model of a control system?

622


relation between power station capacity and voltage level?

1568


what the Microsoft .NET framework is?

1467


For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is

697


what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips

1060


why dc is used in control circuit for mv & hv switchgear instead of ac

1433


transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?

1627


What is a surge supressor why its is used in synchronous generators

1510


which stabilizer is better ? AVR, Servo Stabilizer, Static stabilizer etc & why explain it

2395


Define active filter?

572