Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why birds seating in HT line does not get shock?
If person hangs in HT line (single hand or both hands) does
he get shock?

Answer Posted / arun kumar

Birds seating in HT line does not get shock because circiut
doesnot complete .If man hangs in the single line also he
wont get th shock beacuse ther is no complete path for
current to flow .but if Man or Bird touches other line and
there would be closed circuit now and there shold be shock .

Is This Answer Correct ?    79 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?

1877


why power not passes in plastic and rubber material

1949


Explain M Var? Which types of problem occurs when reactive power increase at the time of full load of plant and at the time of synchronize of plant?

1756


how braking & making capacity of circuit breaker are calculated?

2286


what are the dimensions for 200 kva transformer plinth (plateform),in which pcc m20 is used..

11664


What are the applications of autotransformers?

1060


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

1923


Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.

2371


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2742


What is cable tray, its type, and its support?

1137


what is the reactive power what is the use of it in system

2144


Give some differences between open loop and closed loop?

1092


is it possible to have dc motors on single chip

1814


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1522


Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?

1692