Questions :-
HR-
Q.1 about yourself & family background ?
Q.2 Why u choose Power sector as ur carrier starting not any
other sector ??
Q. 3 What think abt NTPC ?
Techincal Questions:-
Q.1 about Vocational Training……What u did , see the main
equipments….etc
Q.2 Why a transformer Noise during its running condition ?
Q.3 about transformer oil material & Test name for the
measurement of its dielectric strength & wht will u do if
its dielectric strength goes low ? ……..some discussion type ?
Q.4 What is relation between transmission lines &
Communication lines ?
Q.5 Which Machine u will prefer to use at a place where
flammable gases are coming out & why ?
Q.6 how fault in an electric system is detected & hw
protection of equipments is done ?
Q.7 Why we didn’t feel electric shock in an electric train ??
Q.8 Anything u want to ask from us ??
Answer Posted / simanchal
Please send me the ans related to the above question please.
My email id is simanchal.sahu6158@gmail.com
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance
what type of motor used to move a 1 ton gate? and relate ratings with load.
Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?
what is the difference between ac motor and dc generator
Why PS class CT is always preferred for Differential protection?
1. transformer design formula ? 2. how to calculate the primary turns and secondry turns ? 3. core types ? 4. how to find the primary current and secondry current ? 5. how to calculate the stacking factor ? 6. range of fulx density ?
If oil and air can withstand a high MeV when used as an insulator in a transformer, what are the values of how high for each material?
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?
why all the feeders are designed in a particular manner ... is there any reason for that???
Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above
The slip during plugging operation is given by= A 1-s B 2+s C 1+s D 2-s
WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?
What is the difference between the impedance percent and impedance voltage ?