Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Generator protection &generator test

Answer Posted / sumit mishra from areva t&

Protection required for dectection of abnormal(fault) condn
in case of generator are called generator protection.

Proetction req is based on the rating of the generator.
Following are some protection req in case of Generator.
1.Under/over voltage
2. Under/Over freq
3. Reverse Power
4. Differential Protection
5. Voltage controlled/restrained O/C
6. Loss of Filed
7. Stator E/F
8. Rotor E/F
9. Negative sequence/unbalance
10 Pole slipping etc..

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1918


what is the purpose that we use PLC system in power system

5047


.php|

2152


Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?

1814


for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2073


in single phase converter, the no.of scr's conducting during overlap a)1 b)2 c)3 d)4

2050


What are the types of instrument transformer?

1160


How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.

4766


what is servo motor and how it works?

2284


Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?

2249


is IS says that neutral should be brought to switch box. and this one is a recomended practice

1845


where is the need for short circuit test for 3 see is required and why? can you explain in brief with application

1939


What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?

1916


how to find Harmonics and types as per the equipemnts

1262


how to get bearing & winding temperature of an induction motor?

2003