Answer Posted / sumit mishra from areva t&
Protection required for dectection of abnormal(fault) condn
in case of generator are called generator protection.
Proetction req is based on the rating of the generator.
Following are some protection req in case of Generator.
1.Under/over voltage
2. Under/Over freq
3. Reverse Power
4. Differential Protection
5. Voltage controlled/restrained O/C
6. Loss of Filed
7. Stator E/F
8. Rotor E/F
9. Negative sequence/unbalance
10 Pole slipping etc..
Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
How can I calculate ISF of current transformer?
what is the control circuit for operating the clean room air shower
What products have you designed which have entered high volume production?
Why we use ups battery and dsdb battery in thermal power plant
what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct
what happen if generator of micro hydro running at only a small percentage of its capacity, as a comparison, if the diesel generator that runs on only a fraction of its capacity there will be a wet stacking
What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
why 1.7Uo for HV cable Hi pot test?IE standard why?
why magnet has north and south poles only why not east and west and why we are considering as north and south poles? why cant we consider as east and west?
How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?
What is the effect of pd controller on system performance?
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
2 v/500amp/hr to 1.80vpc at 20 degree celsious 2v/5ooamp/hr to 1.75 vpc at 77degree farren .this is the capacity of a battery .what is the meaning of this . can i get a detailed explenation
detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron