Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can any body tell me what is use of END OF LINE RESISTOR in
fire alaram circuit?

Answer Posted / kevin hackart

THE END-OF-LINE RESISTOR IS USED IN MOST ALARM SYSTEMS AS A
CABLE FAULT MONITORING DEVICE, EG.CABLE CUT BY INTRUDER.
THE MAIN CIRCUIT USES A SPECIFIED RESISTANCE AND THE MOMENT
THAT VALUE ALTERS OR DISAPPEARS IT TRIGGERS THE ALARM. ALSO
WHAT COULD BE USEFUL IN FIRE ALARMS IS IF THE CABLE IS
BURNT OFF OR HEATED THUS CHANGING THE RESISTANCE FURTHER
DOWN THE LINE IT WILL ALSO TRIGGER THE ALARM AND COVER FOR
A FAULTY DETECTOR. MAINLY THE RESISTOR IS FOR TAMPERING AS
MOST SYSTEMS USE A NORMALLY CLOSED LOOP AND SO IT IS EASY
FOR SOMEONE TO JUST SHORT OUT THAT CIRCUIT WITH A PIECE OF
WIRE, A SPECIFIC RESITANCE MAKES IT TOUGHER TO BE BYPASSED.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative

2112


how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............

2059


According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.

4155


why does make gain margin and phase margin on same plot.?

2073


testing of Vector Group – YNaoD II

2915


I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1803


what is meant by impedance & transient protection?

2094


What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?

1649


what is the main parts of transformer? how it is functioning? pls giv the ans briefly.

1937


the typical output of a solar cell is........

2339


WHAT IS THE USE OF PIG TAIL IN WINDOW CT ?

2519


i applied for c licence with my one year apperents trainee and i have attaced with A grade contractor company experiance that is for 14 monts experiance this document is sufeicant for c licence? pls tell why they rejected

2228


How do we calculate the resistance per metre of single core aluminium stranded cable 19*3.25mm sheathed in pvc,at 15 deg C temperature?

2385


How can we calculate the efficiency of a Running (On-Load) Motor ? What parameters are required and what is the method ?

1957


what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.

1859