any body tell me ,contol valve has how many cheractristic?
explain it.
Answer Posted / sukumar
control valve three types of cheracterstics
equal % means give 50% valve opening 35%
liner means give 50% valve opening 50%
quick opening means give 50% valve openig 65%
| Is This Answer Correct ? | 5 Yes | 13 No |
Post New Answer View All Answers
what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
please tel me the calibration of pneumatic controler.
What is the meaning of wet leg
How to work temperature gauge?
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
How do you identify an orifice in the pipeline?
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
Explain operation of Haskel pump.
Describe the function of Accumulator into the Pump
How do bending tubing provide better measurement than using tubing fittings such as elbows?
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer