Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In VSD (variable speed drive)I/P and O/P connections given
wrongly what will happen?

Answer Posted / amit.sonmale

If I/P & O/P IS Conected with each other Then There will
not control on speed of motor It means Motor will directly
Conect with Suply.

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

difference between crane drive and line drive.

1886


How relay coordination has to be done? what are the inputs are required for this? Please explain this with calculation method?

1778


what is the differebt between ac and dc fuse?

2321


State the types of distortions in amplifier?

1188


what is the effect of un-synchronized power.

2035


12.5 tons a/c is their how much kva generator can recommend to the customer.

2008


why do we carry out winding resistance test?

2272


there are cam operated switches - why we call cam operated , What is cam ?

1897


we have an energy meter in a capacitor bank panel, So should we consider it's readings as energy consumption on daily basis. (when capacitor bank doesn't have any energy losses)

2395


What is the function of a neutral reactor.

1856


we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.

1906


i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester

2150


how to extend relay operating timing in 24V dc relay card (without using Timer )

1984


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2464


is there any chart showing the suitable cable size according to AMP and length ? for three phase motors

1385