who much should be the lap length in reinfocement
Answer Posted / hanish sehgal
its 50d
d = diameter of bars
Is This Answer Correct ? | 23 Yes | 5 No |
Post New Answer View All Answers
what would be the design load of R.C.C Cooling tower per cell.?
could u tell me how to used deform stell bar in reinforce concret?i wanna know the general using in the site!
how to convert cement, sand aggregate quantity from M3 to kg with full description?
how u design STAGING for Superstructure in BRIDGE construction?
The properties of concrete HA-30 and how does it differ with M 30 (specify the important characteristics like workability,strength,mix design,slump test value)and what is the standard relating to it
why we use for testing of compression strength concrete the size of specimen 150x150x150. why we are not using another dimension like 100x150x100 uneven dimension.
In foundation design, while we do the base pressure check, we normally check if the attained pressure value is less than the GROSS BEARING CAPACITY of the soil which is the sum of net bearing capacity of soil and the overburden pressure. Actually, the overburden pressure acts against the net bearing capacity of the soil and I feel that we are actually increasing the bearing capacity value and doing the check. I feel that this is NOT right. Please clarify on this.
As per Kandal suggestions, we have implemented rolling starts on 140 (+/- 5) degrees and we kept 3 rollars to complete the rolling before falling 125 degrees and the Aggregate AIV is below 22. But When the DBM bed is being rolled 3rd high viabration, (Before 1 plain & low ,2 high Viabrations), the aggregate is getting sharp edge agg. projections are damaged. As the literature is said that, the VG-30 Grade having better control the temp. susceptibility than Penetration grade. if so we could not get this problem at site. But we are facing on site. let me know.
Define What is made from large rocks, which protects the base of cliffs?
Dear Frds, How can i calculate the Steel for RCC Slab, Please provide one Example also, so that i can understand very well. Ex: Area: 1320.0 Sft.(44' X 30') Span: 15'(Default). Column Size: 9"X15"(6 No.s 12mm Rods) Please Provide Calculation Details. Thankyou. Satish
if dia of slab beam bar is38mm what its clear cover any method of provide clear cover
Curing time for 1)R.C.C slab 2)B.W 3)Plastering
The 4 main factors to start a construction project are––
IS THERE ANY JOBS FOR THOSE WHO ARE IN FINAL YAER OF ENGINEERING(CIVIL) IN MUMBAI
what is flexible and rigid footing?