Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

generally on the roadside v hav 11kv line which is being
step down to 440v line to line....so any1 can tell me which
type of transformer they r using whether it is star to
delta,delta to star etc...???

Answer Posted / sabale.dnyanehswar@gmail.com

generally it will be 1.1 kv/0.415kv step down star -delta
transformer.

Is This Answer Correct ?    3 Yes 22 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1923


what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2431


Why the output of OP-AMP is always less than Vcc?

1979


What are hrc fuses and where it is used?

1234


why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.

1893


i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?

2121


What is the test block protection relay if any body know plz explained

1523


show the single line diagram of star delta starter with single phase preventer

4695


What is the working principle of MIG welding? and its out put Voltage?

3395


WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.

3521


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1890


What are protections for dty type transformers

1885


In dc ckt. 24v or 110v, which one is more efficient and why?

2291


WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?

5144


if a.c supply is given to the motor,, what happen?

2221