Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what the purpose of transmited high voltage in over head
lines

Answer Posted / ks

because high voltage. if we want transmit HT through UG
cables it is so costly due to need of very high insolation

Is This Answer Correct ?    1 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can u tell me design of switch yard

2150


8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......

9257


what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights

1922


What is the types of HT motor testing

3563


please send the IS strandard for electrical to sakthi_murugan86@yahoo.co.in

2246


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2141


state the working of discharge lamp?

2001


WHAT IS START TO INDUCTION MOTER IN STAR TO DELTA OF >5HP ?

1857


What is the formula to calculate a three phase alternator

2321


What are the advantages of vscf wind electrical system?

1076


How could I get a certificate of competency as Electrical Supervisor? I have completed By BTech in Electrical this year(2012) for VJTI Mumbai Maharashtra. Is it compulsory to be produced while joining?

3429


do we use neutral grounding for resistive balanced load? if we use what happen?

1777


salam,hi, i need to know what the spesification of 300amp msb...

2017


a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn

1535


What is corkscrew rule?

1135