Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In AC Drives How can change & control its output Frequency?

Answer Posted / felixraj

by Invertors(cycloconvertors).only condition is to maintain
V/F ratio

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is gas turbine intercooling ?

2165


Why CBCT rating is 50/1A

2924


Is there any specialised book to refer about fault level calculation both in MV and LV side??

2125


WHAT IS DEGREE OF COMPOUNDING IN D.C MACHINE MEANS? HOW TO READ THE OPERATING CHART FOR ANY ELECTRICAL MACHINES?

4922


calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.

3624


What is creepage distance..... what will be the value for different voltage level

2026


Write a note on materials used as a fuse element.

2175


Why did lightening arrestor solid copper rod head is sharp on mobile tower top?

2064


Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?

1772


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1743


What will happen if we introduce negative feedback to a control system that uses a positive feedback?

1148


why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)

2519


What is the earth treantment procedure?

2131


What do you mean by screen of power cables?

1851


Difference between low impedance and high impedance Restricted Earth Fault

3156