Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

defination of reactor

Answer Posted / t.k

Reactor is a electrical device which use to store the
current in Maznetic field. or u can say it is use to limit
the current.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?

2054


What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.

1699


What is 100% protection of generator? Why 100% is not used but 95% is generally used?

986


Why field rheostat is kept in minimum position?

1174


why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

1935


why the neutral point in connnection oscillates?

2213


while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?

1868


What are the advantages and disadvantages of open loop control system?

1056


What will happen if the voltage in my house drops from 220V to any lower voltage?

2126


How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?

2062


need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.

1776


What are the types of feedback oscillators?

1229


Why we use mho Relay in long transmission line?

1394


Explain about Leakage Test.

1936


as a electrical student why should i hire you?

2441